CO-DS1 (DS1 CO Trunk)
Table 155. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1020
ABORT
2000
ABORT
2100
ABORT
2053
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
Response to the test request was not received within the allowable time
period.
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
At least one of the following errors was found on the DS1 circuit pack: loss
of signal (1281), blue alarm (1793), red alarm (2049), yellow alarm (2305),
or hyperactivity (1537).
1. Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining station,
trunk, or external wiring.
Continued on next page
Issue 5 October 2002