Table 177. TEST #111 Data Channel Local Loop Back Test — Continued
Error
Test
Code
Result
FAIL
PASS
The target DATA-CHL is functioning. Connections can be established over
the target DATA-CHL.
974
Issue 5 October 2002
Description/Recommendation
c. If the result of Test #107 is PASS and the result of Test #108 is
PASS, then the target DATA-CHL is defective.
1. Issue the remove data-module command.
Replace the Processor circuit pack at your earliest convenience.
After the Processor circuit pack has been replaced, its
Time-of-Day clock must be set using the set time command.
2. Restore any busied out function (PRI-CDR/SEC-CDR,
SYS-PRNT, PMS-PRNT/JNL-PRNT, PMS-LINK) to service
before moving on to another activity.