PMS-LINK (Property Management System Link)
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to the
extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
Table 398. TEST #215 Link Retry Test
Error
Test
Code
Result
10
ABORT
Internal System Error.
20
1. Retry the command at 1-minute intervals a maximum of 5 times.
30
ABORT
Internal System Error.
1. Refer back to the
1010
ABORT
The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
2. Retry test pms command to execute the test.
FAIL
The PMS Link CANNOT be established.
1. Refer back to the
PASS
The PMS Link is up.
555-233-119
Description/ Recommendation
''Procedures for Restoring the PMS Link''
resolution.
state.
''Procedures for Restoring the PMS Link''
restoring the PMS Link.
section for
section for
Continued on next page
Issue 5 October 2002
1489
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers