Avaya DEFINITY Server CSI Maintenance Manual page 1392

Table of Contents

Advertisement

Maintenance Objects
Table 361. TDM NIC Looparound Test (#1380) — Continued
Error
Test
Code
Result
Description/ Recommendation
2000
ABORT
Response to the test was not received in the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error.
2801
ABORT
The TN802B/TN2302 Media Processor board has not been
administered on the ip-interfaces form.
ANY
FAIL
The test did not detect the test tone through the looparound
connection.
PASS
The board is functioning properly.
0
NO
No board was detected by the test.
BOARD
1392
Issue 5 October 2002
1. Retry the command at 1-minute intervals a maximum of 3 times.
1. Retry the command at 1-minute intervals a maximum of 3 times.
1. Retry the command at 1-minute intervals a maximum of 3 times.
1. Test the tone-clock in the port network that contains the media
processor under test.
2. If the tone-clock is healthy, test the media processor board again.
3. If the test continues to fail, replace the media processor board.
1. Resolve either wrong board (Error 125) or no board (Error 131)
issues, if applicable.
2. Check that the board is properly translated and inserted. If so,
check for hyperactivity (Error 1538). If hyperactive, use the reset
board UUCSS command.
3. Run the test again. If it fails, the NCE chip on board may be bad.
Replace the board and retest.
Continued on next page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents