Avaya DEFINITY Server CSI Maintenance Manual page 1153

Table of Contents

Advertisement

E-DIG-STA (Emulated Digital Line)
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and stations
with an emulated digital voice terminal and a linked data module. Stand-alone
data modules and data adaptors in stand-alone mode are not supported by the
TN800 circuit pack. Circuit pack maintenance is covered by E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
Table 248. Digital Line Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
18(a)
0
busyout port PCSSpp
130 (b)
None
1793 (c)
Voice and Control
Local Loop Test (#13)
2049 (d)
NPE Crosstalk Test
(#9)
2305 (e)
32770
None
3840 (f)
40965
None
3841 (g)
41029
None
2304 (h)
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Notes:
a. Maintenance personnel has busied out the port in question. Make sure that
the port is released from busyout by using the release port PCSSpp
command.
b. The circuit pack has been removed or has been insane for more than 21
minutes. To clear the error, reinsert or replace the circuit pack.
555-233-119
Alarm
Associated Test
Level
Any
WNG
WNG
MIN/
WNG
MIN/
WNG
On/Off
Board
Test to Clear Value
Any
test port PCSSpp sh r 1
OFF
rel port PCSSpp
ON
test port PCSSpp sh
ON
test port PCSSpp l r 3
2
ON
test port PCSSpp l r 3
2
Continued on next page
Issue 5 October 2002
1153

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents