CO-TRK (CO Trunk)
Table 166. TEST #844-848 Transmission Test — Continued
Error
Test
Code
Result
2056
ABORT
FAIL
8000
FAIL
555-233-119
Description/ Recommendation
An error occurred while trying to obtain results from the TN2402/TN798
circuit pack.
1. Test the TN2402/TN798 circuit pack.
Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report with
list testcalls. Make sure that ATMS thresholds are set properly on page 4
of the trunk group form. Besides the facility, test failures can be caused by
faulty test lines or switch paths. If the measurements point to a facility
problem, report the results to the trunk vendor.
Measured transmission performance was in the marginal range as
administered on the trunk group form. This generally means that the trunk is
usable but has an undesirable amount of noise or loss. If the user does not
report unacceptable effects, it may not be necessary to take any action.
Retrieve a measurement report with list testcalls. Make sure that ATMS
thresholds are set properly on page 4 of the trunk group form.
Continued on next page