Io-Procr (I/O Processor) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

IO-PROCR (I/O Processor)

MO Name (in
Alarm Log)
IOP
The I/O Processor includes the I/O Processor CPU, memory, a real-time
operating system, and a driver. Together they support the Data Channel data
scanners and Packet Interface functions. The I/O Processor resides on the single
TN2402/TN798 Processor circuit pack in the system.
Error Log Entries and Test to Clear Values
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
Any
None
257 (b)
Any
None
513 (c)
Any
None
1.
Indicates that an alarm was raised but an associated error was not entered into the hardware error
log due to a momentary overload condition caused by a burst of hardware or software error reports.
Run the long test sequence. Refer to the appropriate test descriptions for any failures and follow the
recommended procedures.
2.
An I/O Processor can only be reset if it has been taken out of service by background maintenance
software.
Notes:
a. Error 1 occurs when background maintenance software has reset the I/O
Processor as a fault recovery action. It is used to track the number of IOP
resets, independent of whether or not the Reset test passed. Once three of
these errors have occurred in the last 15 minutes, maintenance places the
I/O Processor in the out-of-service state, and a MAJOR on-board alarm is
raised on the I/O Processor. When the I/O Processor has been taken
out-of-service, the Packet Interface and Data Channels are also taken
out-of-service.
1. Check to see if error codes 257 or 513 are present in the hardware
2. If no other I/O Processor errors appear in the error log, and if the I/O
1262
Issue 5 October 2002
Alarm Level
MAJOR
Alarm
Level
MAJOR
MAJOR
MAJOR
MAJOR
error log. If one or more of those error codes are present, refer to the
information associated with those errors for the appropriate repair
procedures.
Processor is not in a held reset state as indicated by the absence of
a MAJOR alarm with a Service State of OUT, no action should be
taken.
Initial Command to Run
reset io-processor
On/Off
Board
Test to Clear Value
ON
reset io-processor
ON
reset io-processor
ON
reset io-processor
ON
reset io-processor
Full Name of MO
I/O PROCR
2
2
2
2
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading