Avaya DEFINITY Server CSI Maintenance Manual page 1037

Table of Contents

Advertisement

DIG-LINE (Digital Line)
Table 204. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error
Test
Code
Result
1003
ABORT
1004
ABORT
1020
ABORT
2000
ABORT
1
FAIL
2
PASS
555-233-119
Description/ Recommendation
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR (TTR
Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
The port was seized by a valid call during the test. The test has been
aborted. Use display port PCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use (off-hook)
if the handset is plugged in and the port is not busied out.
Test disabled via background testing. Use status station command to
determine when station is available for testing.
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The Network Processing Element (NPE) of the tested port was found to be
transmitting in error. This will cause noisy and unreliable connections.
Failure code 1 indicates that the Crosstalk test failed on the primary
channel. Failure code 2 indicates that the Crosstalk test failed on the
secondary channel.
1. Replace circuit pack.
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test up to
a maximum of 10 times to make sure it continues to pass.
2. If complaints persist, examine the station, connections, and wiring.
Continued on next page