Asynchronous Commands
You can start, query, and stop an outgoing test call by using the following
maintenance commands:
test isdn-testcall trunk-group-no/member-no [minutes]
This command enables you to start an outgoing ISDN-PRI test call for a
maximum of two hours (120 minutes).
status isdn-testcall trunk-group-no/member-no
This command displays the progress of the outgoing test call by reporting
the bit and block error rates of the tested B-channel specified by the "trunk
group no/member no" identifier.
clear isdn-testcall trunk-group-no/member-no
This command enables you to stop an outgoing test call already in
progress. The trunk-group-no/member-no identifier specifies the
B-channel used to stop the test call. The measurements are not cleared
until the next test call begins.
NOTE:
Only one trunk can be tested in a given port network, until the test call is
canceled or completes.
Table 324. TEST #258 ISDN TEST Call
Error
Test
Code
Result
4
ABORT
8
ABORT
1004
ABORT
1005
ABORT
1018
ABORT
1326
Issue 5 October 2002
Description/ Recommendation
There is a problem with the Processor Interface Link.
1. Refer to PKT-INT (Packet Interface).
There is a problem with the DS1 interface circuit pack.
1. Refer to DS1-BD (DS1 Interface Circuit Pack).
B channel in use.
1. Determine if a call is active on this DS1 ISDN Trunk via the status
trunk
2. When the service state indicates in-service/idle, retry the test.
Bad Configuration (that is, no Maintenance/Test circuit pack)
Issue the test trunk <trunk Group/trunk member> command and make
sure there is a DATA-CHL (NETCON channel) administered.
Test call is disabled.
1. Enable Maintenance on the Trunk Group form.
Continued on next page
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?