Table 168. Data Channel Processor Circuit Pack Error Log Entries — Continued
Aux
Error Type
Data
769 (e)
4358
1025 (f)
4363
1538 (g)
3840 (h)
Any
3999(i)
Any
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This error indicates the DATA-BD portion of the Processor circuit pack
stopped functioning. Since the Processor circuit pack cannot be reset via
the reset board PCSS command, the Data Channel Reset Test (#107) in
the Long Test Sequence for the DATA-CHLs must be used to reset it as
follows:
1. Issue the list data command to determine if one, or more, Data
2. If a Data Channel (DATA-CHL) is not administered, use the add
3. From the form resulting from the list data command, choose a Data
4. Issue the test data-module <ext> long command using the
!
If the red LED stays on, then replace the Processor circuit pack.
946
Issue 5 October 2002
Associated Test
None
NPE Audit Test (#50)
Data Channel Reset
Test (#107)
None
None
Channels (DATA-CHLs) is administered.
NOTE:
A Data Channel (DATA-CHL) is identified by a "type" value of
"netcon."
data-module [<ext> | next] command to administer a DATA-CHL.
Channel (DATA-CHL).
extension for the DATA-CHL chosen in Step 3.
WARNING:
Issuing this command drops all data channel extensions. See
DATA-CHL (Data Channel) Maintenance documentation first.
Alarm
On/Off
Level
Board
test network-control [a | b]
sh
MINOR
ON
test data-module <ext> l
Test to Clear Value