Avaya DEFINITY Server CSI Maintenance Manual page 895

Table of Contents

Advertisement

CLSFY-PT (Call Classifier Port)
Table 152. TEST #42 Tone Detection Verification Test — Continued
Error
Test
Code
Result
101-122
FAIL
PASS
555-233-119
Description/ Recommendation
Forward or Backward MFC signals were not correctly generated or
detected. This impacts reception of incoming MFC calls.
1. Run the short test sequence with test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore system performance to
normal, replace the Call Classifier circuit pack containing the defective
CLSFY-PT (Call Classifier Port).
Tone Detection Verification is successful. The Call Classifier Port
(CLSFY-PT) is able to detect/generate all necessary tones.
Continued on next page
Issue 5 October 2002
895