UDS1-BD (UDS1 Interface Circuit Pack)
Table 524. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Aux
Type
Data
1314(r)
Any
Far CSU Loopback Test
(#1213)
1320
Any
Loss of Signal Alarm
Inquiry Test (#138)
1321
Any
Loss of Signal Alarm
Inquiry Test (#138)
1322
Any
Loss of Signal Alarm
Inquiry Test (#138)
1323
Any
Loss of Signal Alarm
Inquiry Test (#138)
1324
Any
Loss of Signal Alarm
Inquiry Test (#138)
1400,
Any
Loss of Signal Alarm
1401(s)
Inquiry Test (#138) and
Echo Cancellation Test
(#1420)
1537(t)
46082
1538(u)
Any
1793
Any
Blue Alarm Inquiry Test
(#139)
1794
Any
Blue Alarm Inquiry Test
(#139)
1795
Any
Blue Alarm Inquiry Test
(#139)
2049
Any
Red Alarm Inquiry Test
(#140)
2305
Any
Yellow Alarm Inquiry
Test (#141)
2306
Any
Yellow Alarm Inquiry
Test (#141)
2561
Any
Major Alarm Inquiry Test
(#142)
2817
Minor Alarm Inquiry Test
(#143)
3073 to
Any
Slip Alarm Inquiry Test
3160 (v)
(#144)
555-233-119
Associated Test
MIN/WRN
MIN/WRN
MIN/WRN
MINOR
MIN/WRN
WARNING
MINOR
MIN/WRN
MIN/WRN
MAJ/MIN/
WRN
MAJ/MIN/
WRN
MAJ/MIN
/WNG
MIN/WRN
MIN/WRN
MIN/WRN
MIN/WRN
MIN/WRN
MIN/WRN
Alarm
On/Off
Level
Board
3
OFF
test ds1-loop UUCSS
end-loopback/span-test
3
OFF
test board UUCSS
3
OFF
test board UUCSS
ON
test board UUCSS
3
OFF
test board UUCSS
OFF
test board UUCSS
ON
test board UUCSS
3
ON
3
ON
OFF
test board UUCSS
4
OFF
test board UUCSS
4
OFF
test board UUCSS
4
3
OFF
test board UUCSS
3
OFF
test board UUCSS
3
OFF
test Board UUCSS
3
OFF
test board UUCSS
3
OFF
test board UUCSS
3
OFF
test board UUCSS r 6
Issue 5 October 2002
Test to Clear Value
Continued on next page