get boot-image 1C07
Image 1
Board Type: TN2501
FW Vintage: 02
HW Signature: 02
Suffix: A
Date: 03/02/02
Timestamp: 10:30:50
CRC Checksum: Good
Active Image: No
Reboot Image: No
Screen 86. Display Firmware Image(s) screen
6. Ensure that both the Active Image and the Reset Image fields are as
you expect.
Error Log Entries and Test to Clear Values
Table 271. FW-DWNLD Maintenance Error Log Entries
Error
Type
Aux Data
257(a)
See
associated
note
258(b)
See
associated
note
259(c)
See
associated
note
513(d)
See
associated
note
796(e)
See
associated
note
Notes:
a. Error Type 257 — a log only error indicating that a certain software
resource was not available. Such an error very seldom occurs and usually
produces a proc_err. However, in the firmware download feature, the file
1212
Issue 5 October 2002
DISPLAY FIRMWARE IMAGE(S)
Image 2
TN2501
01
02
A
03/02/01
12:42:18
Good
Yes
Yes
Alarm
Cause Of Error
Level
Download failure
MINOR
Download failure
MINOR
Download failure
MINOR
Download failure
MINOR
Firmware
MINOR
download request
On/Off
Board
Test to Clear Value
OFF
test firmware download UUCSS
OFF
test firmware download UUCSS
OFF
test firmware download UUCSS
OFF
test firmware download UUCSS
OFF
test firmware download UUCSS
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers