Maintenance Objects
Table 485. TEST #258 ISDN TEST Call — Continued
Error
Test
Code
Result
2214
ABORT
2215
ABORT
2216
2217
2218
2219
2220
ABORT
2221
ABORT
2222
2223
2224
2225
2226
2227
ABORT
2042
FAIL
PASS
1654
Issue 5 October 2002
Description/ Recommendation
Call terminated by unexpected disconnect.
1. Wait one minute and then try again.
Internal System Error.
1. Follow recommendations for ABORT code 2012.
Call terminated prematurely.
1. Wait one minute and try again.
Internal System Error.
1. Follow recommendations for ABORT code 2012.
Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
This is the main purpose of the test. The comparison of the data sent
with the data received indicates a loss of integrity on the communications
path.
1. The trunk should be taken out-of-service and the quality of the ISDN
Trunk-side BRI line should be investigated. The investigation should
include an in-depth analysis of the facility including the transmission
facility and any external equipment such as DACs, CSUs, etc.
The call worked. A test pattern was sent and received properly; the
communications path is OK if the synchronous test call command was
issued. An in-depth analysis of the ISDN Trunk-side BRI trunk facility
including the transmission facility and any external equipment such as
DACs, CSUs, and others should take place if the bit and block error rates
are not acceptable.
Continued on next page