DIOD-DS1 (DS1 DIOD Trunk)
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
Interface circuit pack to assure that the trunk's translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of trunk kept in the DS1 Interface circuit pack and
in the switch software.
Table 212. TEST #36 Port Audit and Update Test
Error
Test
Code
Result
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Test failed due to internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Trunk translation has been updated successfully. The current trunk states
kept in the DS1 Interface circuit pack and switch software are consistent. If
the trunk is busied out, the test will not run but will return PASS. To verify
that the trunk is in-service:
1. Enter the status trunk command to verify that the trunk is in-service. If
the trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
2. Enter the release trunk command to put the trunk back into in-service.
3. Retry the test command.
Continued on next page
Issue 5 October 2002
1053