Error Log Entries and Test to Clear Values
Table 306. ISDN-PRI Signaling Link Port Error Log Entries
Error
Aux
Type
Data
1
0
0
18(a)
0
130 (b)
1537 (c)
46210
1793 (d)
3585 (e)
46222
3841 (f)
46211
3842 (g)
46223
1.
Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
pp is 24-channel interfaces and 16 for 32-channel interfaces.
Notes:
a. The D-channel is demand busied out. No calls can be made over this
D-channel.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. Link error. This error occurs when the port receives an invalid frame over
the D-channel. This error normally indicates an off-board problem usually
related to transmission errors on the DS1 facility. Execute the list
measurements ds1-log command for the UDS1 TN464 circuit pack on
which the D-channel resides. If the UDS1 is reporting some errors, then the
DS1 facility has experienced transmission problems which could have
caused the ISDN-PLK to report a Link Error. If the UDS1 is not reporting
errors, execute the long test sequence for the D-channel (ISDN-SGR).
Investigate any errors, if there are none execute a long test sequence for
the UDS1 circuit pack (UDS1-BD) and investigate any errors.
If no errors are reported, the Link Error is probably not affecting service.
d. The UDS1 Interface circuit pack is out-of-service. Look for and resolve
UDS1-BD errors in the Hardware Error Log.
1284
Issue 5 October 2002
Associated Test
Any
busyout port PCSSpp*
None
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
WARNING
OFF
MINOR
ON
Test to Clear Value
2
test port PCSSpp
2
release port PCSSpp
2
test port PCSSpp
2
test board PCSSpp
1
555-233-119