Maintenance Objects
AXA12-RS/ADX8D-RS/AXD12-RS
(AUDIX Reserve Slots)
MO Name (in
Alarm Log)
Alarm Level
AXA12-RS
NONE
ADX8D-RS
NONE
AXD12-RS
NONE
There are no tests associated with these MOs. Both the test board and busy out
board commands abort when either is attempted on a reserved slot. An error
message indicates that the slot is associated with the circuit pack that the TN568
is emulating, but the requested operation is not valid. If there are errors logged
against these maintenance objects, see XXX-BD.
The TN568 circuit pack connects to the switch through a single slot in the
backplane; however, the number of slots physically occupied by the circuit pack is
supplied by the board when inserted. The TN568 is 2 slots wide: the functional
slot and a reserve slot. The reserve (blank) slot to the left of the functional slot is a
place holder on the switch and has no interaction with the switch.
These MOs are place holders for the extra slot needed for the EMBEDDED
AUDIX board. Each instance of these MOs represents a reserve slot associated
with the respective circuit pack mode in which the TN568 (EMBEDDED AUDIX) is
working. They are used for embedded AUDIX and emulation of respective port
types.
788
Issue 5 October 2002
Initial Command to Run
NONE
NONE
NONE
Full Name of MO
TN568 12-port analog reserve slot
TN568 8-port digital reserve slot
TN568 12-port digital reserve slot
555-233-119