Maintenance Objects
NIC Query Test (#1383)
This test is non-destructive.
This test passes if the Ethernet port is connected and you can talk on the network.
Otherwise it fails with no fail code or AUX data.
Table 357. TEST #1383 NIC Query Test
Error
Test
Code
Result
Description/ Recommendation
None
ABORT
System resources required for this test are not available.
1015
ABORT
Port is not out-of-service.
2100
ABORT
System resources required for this test are not available.
FAIL
network.
PASS
0
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the
port.
1386
Issue 5 October 2002
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the command again.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The Ethernet port is not connected and you cannot talk on the
The Ethernet port is connected and you can talk on the network
1. Ensure that the board translations are correct. Administer the
MedPro interface if it is not already administered.
2. If the board was already administered correctly, check the error
log to determine whether the board is hyperactive. If this is the
case, the board is shut down. Reseating the board re-initializes
the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
Continued on next page