OPS-LINE (DS1 OPS Line)
Table 374. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1002
ABORT
1003
ABORT
1004
ABORT
1020
ABORT
2000
ABORT
2100
ABORT
555-233-119
Description/ Recommendation
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of 5 times.
The test was aborted because the port was seized by a user for a valid call.
Use status station command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test did not run due to an already existing error on the specific port or
due to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error. (Error code
1793 indicates a problem with the DS1 interface board, and any
problems on the associated DS1-BD or UDS1-BD should be resolved
first.)
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test aborts with error code 2000 again, run short test sequence on
the associated DS1-BD or UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting with error code 2000,
hyperactivity on the board or facility is indicated. In this case, the
hyperactivity problem should be dealt with first.
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page