Table 180. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
1002
ABORT
1003
ABORT
1004
ABORT
1020
ABORT
2000
ABORT
2100
ABORT
Any
FAIL
PASS
980
Issue 5 October 2002
Description/Recommendation
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to "TDM-BUS" to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
The port has been seized by a user for a valid call. Use status
data-module to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test did not run due to an already existing error on this port (Error Type
769).
1. Refer to the procedure for Error Type 769. If Error Type 769 still occurs
on this port, replace the circuit pack.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests, examining the ADU,
external wiring, and customer equipment.
Continued on next page