Hardware Error Log Entries and Test to Clear
Values
Table 286. Hybrid Line Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1 (a)
Any
None
15 (b)
Any
Hybrid Audits Test
(#61)
18 (c)
0
busyout port
PCSSpp
130 (d)
None
257 (e)
40988
None
513 (f)
40965
Hybrid Line Audits
Test (#61)
769 (g)
Remote Dig Loop
Around Test (#59)
1025
Hybrid & Conf.
Circuits Test (#57)
1281
Local Digital Loop
(h)
Around Test (#58)
1537 (i)
40968
None
1793
TDMNPE Crosstalk
Test (#6)
2049 (j)
32770
None
2049 (k)
40967
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values
used in the set options command.
Notes:
a. Indicates a defective data link. An off-board problem was detected by port
circuit. Verify that the Hybrid set is connected and that the EPF test passes.
If data transmission problems are experienced, check for defective wiring
or a defective voice terminal, or move terminal closer to the switch (in
terms of feet of wire from the jack to the switch). If the problem still exists,
replace the circuit pack. Once the problem has been resolved, the alarm is
retired after a predetermined period of time.
1238
Issue 5 October 2002
Alarm
Associated Test
Level
Any
WARNING
WARNING
WARNING
MIN/WRN
WARNING
WARNING
MIN/WRN
WARNING
WARNING
MIN/WRN
On/Off
Board
Test to Clear Value
Any
test port PCSSpp sh r 1
OFF
OFF
release port PCSSpp
ON
test port PCSSpp sh
2
OFF
OFF
test port PCSSpp sh r 4
OFF
test port PCSSpp sh r 3
2
ON
test port PCSSpp l r 3
ON
test port PCSSpp l r 3
OFF
2
ON
test port PCSSpp l r 3
Continued on next page
555-233-119