Avaya DEFINITY Server CSI Maintenance Manual page 1012

Table of Contents

Advertisement

Port Audit Update Test (#36)
This test sends updates of the DID port translation for all ports on the circuit pack
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes: wink or immediate start trunk, dial tone or
rotary dialing trunk, rotary dialing inter-digit timing, Network balance R/RC, and
disconnect timing.
Table 192. TEST #36 Port Audit Update Test
Error
Test
Code
Result
ABORT
1006
ABORT
2100
ABORT
FAIL
PASS
1012
Issue 5 October 2002
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The port has been placed out of service, perhaps by craft busyout. Use the
display port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is out of
service, then the port is unavailable for certain tests. You must wait until the
port is in service and idle before retesting.
1. If the port status is in service and idle, then retry the command at
1-minute intervals for a maximum of 5 times.
Could not allocate the necessary system resources to run the test.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test passed. Translation information was successfully updated on the
circuit pack.
1. If signaling troubles are reported (Error Types 1, 257, or 513 in Error
Log table), verify translation information for this port.
2. Refer problem to the CO. If the trunk is busied out, the test does not
run, but returns PASS.
To verify that the trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is out-of-service,
continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents