PPP-PT (Control LAN Packet/Port)
g. Error Type 1793-1920: system software received an indication that a
socket was closed due to an error. Error Type indicates the application
associated with this socket.
Error Type
1793
1794
1795
1796
1797
1798-1920
Aux Data indicates the internal application number.
h. Error Type 2305-2816: System software detected a session is down. Aux
Data indicates the session number. These are log only errors. Error types
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for
session numbers 257-512.
i. Error Type 3329: TCP/IP Ping Test failed.
1. Test the port (test port UUCSSpp short).
2. Refer to TCP/IP Ping Test (#1281) repair procedures.
j. Error Type 3585: TDM Port Looparound Test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. Refer to TDM Looparound Test (#1285) repair procedure.
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate errors in the order they appear in the table below.
Table 403. System Technician-Demanded Tests: PPP-PT
Order of Investigation
TDM Looparound Test (#1285)
SCOTCH Synchronous Looparound Test (#1275)
TCP/IP Ping Test (#1281)
Session Status Test (#1286)
PPP Link Status Test (#1279)
1.
D = Destructive, ND = Non-destructive
555-233-119
Application
Unused
DCS
AUDIX
CMS
ISDN
Gateway
Reserved for
future
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
Issue 5 October 2002
1
D/ND
D
D
ND
ND
ND
1499