HYB-LINE (Hybrid Line)
PBX
Figure 30. Hybrid Station Interactions
This section refers only to the HYB-LINE (Hybrid Line) maintenance that is
performed. Please note that the HYB-LINE (Hybrid Line) maintenance is closely
related to, and interacts with, the HYB-BD (Hybrid Line circuit pack) maintenance
in some instances. Some of the results of maintenance testing of the Hybrid Line
may be affected by the health of the Hybrid Line circuit pack. This interaction
should be kept in mind when investigating the cause of reported Hybrid Line
problems.
There are instances in this section where "service states" of a station are
mentioned. It is helpful to understand what is meant by the different service states
that may exist. An explanation of these service states follows:
Out-of-Service–The port, and thus the station, have been removed from
service. A busyout of a port causes it to be out-of-service.
Ready-for-Service–Once a port on the circuit pack has been put into
service, the voice terminal must communicate that it is present. The time
between these two events is the time when the terminal is in the
ready-for-service state.
In-Service–Once the system has received a message from the voice
terminal communicating that it is present, the station is put into the
in-service state. The terminal can also be forced into the in-service state if
it goes off-hook while it is in the ready-for-service state.
When the status station command has been run, and the status screen appears,
the status is reported as either out-of-service or in-service, which mean exactly as
stated in the above list, or disconnect, which means the station is in the
ready-for-service state.
555-233-119
HYBRID
LINE
CIRCUIT
PACK
(1)
PORT
(8)
PORT
VOICE
TERMINAL
VOICE
TERMINAL
HYBRID LINE
Issue 5 October 2002
1237