Maintenance Objects
Digit Detection Test (#297)
This test is executed on the Non-Control Channel bus. The Tone-Clock circuit
pack is told to put a tone on the Non-Control Channel bus and the Tone Detector
circuit pack is told to listen to it. The test passes if the tone is successfully
transmitted on the Non-Control Channel bus.
Table 489. TEST #297 Digit Detection Test
Error
Test
Code
Result
none,
ABORT
1001
2100
1005
ABORT
2000
ABORT
none
FAIL
PASS
1666
Issue 5 October 2002
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
Since this test is valid only on the non-control channel bus, it aborts
execution when run on the control channel bus. This is a valid response.
Use the status system command to verify which bus is the control channel
bus.
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This failure indicates that communication on the Non-Control Channel is not
reliable.
1. Execute the command again.
2. If the problem persists, test the Tone-Clock circuit pack and Tone
Detector circuit pack to make sure they are healthy. Refer to TONE-BD
(Tone-Clock Circuit Pack), TONE-PT (Tone Generator), GPTD-PT
(General Purpose Tone Detector Port), and DTMR-PT (Dual Tone
Multifrequency Port).
3. Execute the command again.
4. If the problems persists, refer to the
Isolation Procedure''
The non-control channel bus is operational.
''TDM Bus Fault Detection and
described earlier.