DS1-BD (DS1 Interface Circuit Pack)
Table 221. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Aux
Type
Data
1324
Any
Loss of Signal Alarm
Inquiry Test (#138)
1538 (q)
Any
1793
Any
Blue Alarm Inquiry Test
(#139)
1794
Any
Blue Alarm Inquiry Test
(#139)
1795
Any
Blue Alarm Inquiry Test
(#139)
2049
Any
Red Alarm Inquiry Test
(#140)
2305
Any
Yellow Alarm Inquiry Test
(#141)
2306
Any
Yellow Alarm Inquiry Test
(#141)
2561
Any
Major Alarm Inquiry Test
(#142)
2817
Minor Alarm Inquiry Test
(#143)
3073 to
Any
Slip Alarm Inquiry Test
3160 (r)
(#144)
3329 to
Any
Misframe Alarm Inquiry
3345 (s)
Test (#145)
3840(t)
Any
None
3900(u)
Any
CPE Loopback Jack Test
(#1212)
3901(v)
Any
Far CSU Loopback Test
(#1213)
3902(w)
Any
One-Way Span Test
(#1214)
3999 (x)
Any
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
555-233-119
Associated Test
Alarm Level
WARNING
MINOR
MAJ/MIN/
WRN **
MAJ/MIN/
WRN **
MAJ/MIN/
WRN **
MIN/WRN†
MINOR
MINOR
MIN/WRN†
MIN/WRN†
MIN/WRN†
MIN/WRN†
On/
Off
Board
Test to Clear Value
OFF
test board UUCSS
ON
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS
OFF
test board UUCSS r 6
OFF
test board UUCSS r 6
Continued on next page