PR-MAINT (Maintenance Processor)

MTP Outpulse Relay Test (#102)

This test is a nondestructive test. The test validates the correct operation of the
remote access CO trunk used by INADS. The MTP first goes off-hook, then
on-hook on this trunk. If the loop current is detected, the test passes. This test is
not allowed if the remote access line is in use.
Table 411. TEST #102 MTP Outpulse Relay Test
Error
Test
Code
Result
1029
ABORT
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
1018
ABORT
1131
ABORT
10201
ABORT
10202
ABORT
10203
ABORT
555-233-119
Description/ Recommendation
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
The test has been disabled via administration.
1. To enable the test, issue the change system-parameters maintenance
command, and set the test remote access port field to "y." (If you have
an INADS line, set the field to "y." If you are testing the Standby
PR-MAINT, a refresh spe-standby command must be successfully
executed before you proceed to Step 2.
2. Rerun the test.
INADS port is busy because the system is reporting alarms to INADS, or
because INADS is dialed into the system.
1. Wait about ten minutes and then re-enter the command.
System software resources required to run this test are not available.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
MTP did not respond to the test request.
1. Repeat the test at 1-minute intervals a maximum of 5 times.
2. If all MTP tests are aborting, execute the test processor a/b long
command in order to reset MTP and to examine the results of the MTP
Reset Test (#101).
3. Replace the Processor circuit pack.
4. If only the MTP outpulse relay test is aborting, escalate the problem.
Continued on next page