ETH-PT (Control LAN Ethernet)
Link Integrity Inquiry Test (#1282)
This non-destructive test queries the CLAN Ethernet port's physical connections.
If:
CLAN connection is present,
CLAN connection is absent,
There is no response,
Table 259. TEST #1282 Link Integrity Inquiry Test
Error
Test
Code
Result
1124
ABORT
1125
ABORT
1959
ABORT
2012
ABORT
2100
ABORT
555-233-119
Then the test:
Passes.
Fails.
Aborts.
Description/ Recommendation
Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
Continued on next page
Issue 5 October 2002
1173