Maintenance Objects
This test is not executed for ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT
because the B-channels associated with the port are not used by ASAI or
adjuncts.
Table 110. TEST #161 Loop Around Test
Error
Test
Code
Result
1000
ABORT
1004
ABORT
1005
ABORT
2012
ABORT
2100
ABORT
1, 2
FAIL
PASS
804
Issue 5 October 2002
Description/ Recommendation
System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension or trunk group/member number of the port.
Use the status bri-port PCSSpp command to determine the service state
of the port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. Wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port and determine when the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test is not valid for this type of translation. Ports administered as
"ASAI" or "ADJK" can not run this test, because the B channels associated
with the port are not used by ASAI or Adjunct Links. This is a normal
condition.
Internal system error
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections. Error code 1 indicates that the
NPE Crosstalk Test failed on Channel B1. Error code 2 indicates that the
NPE Crosstalk Test failed on Channel B1.
1. Replace circuit pack.
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test a
maximum of 10 times to make sure it continues to pass.
2. If complaints still exist, examine the station, connections, and wiring.
Continued on next page