Emg-Xfer - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

EMG-XFER

Emergency Transfer (SCC Cabinets)
MO Name (in
Alarm Log)
EMG-XFER
EMG-XFER
1.
Where P is an appropriate port network number determined via the PORT field from the
Alarm or Error Log.
The system provides the ability to cut designated analog phones through to CO
trunks if the switch cannot provide even minimal phone service. This ability is
known as Emergency Transfer. The EMG-XFER MO tracks the control of
Emergency Transfer. There is one EMG-XFER MO for the port network.
Emergency Transfer can be controlled by the system or can be manually
controlled via the Emergency Transfer switch located on the Processor circuit
pack. A manual ON position (up) generates a Major alarm. A manual OFF position
(down) generates a Warning alarm. Unless a technician is currently working on
the system, the switch should be left in the auto position.
Error Log Entries and Test to Clear Values
Table 252. Emergency Transfer Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1
Any
Emergency Transfer
Query (#124)
257
0
Emergency Transfer
Query (#124)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
1162
Issue 5 October 2002
Alarm
Level
Initial Command to Run
MAJOR
test environment P
WARNING
test environment P
Alarm
Level
Any
MAJOR
WARNING
1
Full Name of MO
Emergency Transfer
Emergency Transfer
On/Off
Board
Test to Clear Value
Any
test environment P sh r 1
ON
test environment P r 3
ON
test environment P r 3
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents