EXT-DEV ADMIN? N (External Device
Alarm)
MO Name (in
Alarm Log)
EXT-DEV
EXT-DEV
1.
Where P is an appropriate cabinet number determined via the PORT field from the
Alarm or Error Log.
NOTE:
Use this Maintenance Object when the External Device Alarm
Admin? field on the change system-parameters customer-options form is
set to n.
The Processor in carrier A monitors the EXT-DEV alarm leads. The system only
recognizes pairs connected to the 1M and 1m (ALARM MONITOR) leads. Refer
to the DEFINITY Communications System Generic 1 and Generic 3i Wiring,
555-204-111, for more details.
Hardware Error Log Entries and Test to Clear
Values
Table 264. Hardware Error Log Entries and Test to Clear Values
Error
Aux
Type
Data
1
0
0
Any
1 or 5
Any
External Device
Alarm Test (#120)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
One port generates a MAJOR alarm; the other port generates a MINOR alarm.
1184
Issue 5 October 2002
Alarm
Level
Initial Command to Run
MAJOR
test environment P
MINOR
test environment P
Alarm
Associated Test
Level
Any
MAJOR
MINOR
1
External Device Alarm
External Device Alarm
On/Off
Board
Test to Clear Value
Any
test environment UU r2 or
6
OFF
test environment UU r 2
2
or 6
Full Name of MO