Avaya DEFINITY Server CSI Maintenance Manual page 1488

Table of Contents

Advertisement

Maintenance Objects
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Link Retry Test,
for example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
Link Tear Down Test (#213)
Link Retry Test (#215)
1.
D = Destructive; ND = Nondestructive
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external PMS
device. If the link has been disconnected already, then this test just returns
"PASS." All resources allocated for a PMS Link are released after this test.
Table 397. TEST #213 Link Tear Down Test
Error
Test
Code
Result
40
ABORT
Internal System Error.
50
1. Retry the command at 1-minute intervals a maximum of 5 times.
1010
ABORT
The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
2. Retry test pms long command to execute the test.
FAIL
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The PMS Link is torn down.
1488
Issue 5 October 2002
Description/ Recommendation
state.
Short Test
Long Test
Sequence
Sequence
X
X
X
Continued on next page