ETH-PT (Control LAN Ethernet)
g. Error Type 2305-2816: System software detected a session is down. Aux
Data indicates the session number. These are log only errors. Error types
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for
session numbers 257-512.
h. Error Type 3329: TCP/IP Ping Test failed.
1. Test port (test port UUCSSpp short).
2. Refer to TCP/IP Ping Test (#1281) repair procedures.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors in the order they appear in the table below.
Table 256. System Technician-Demanded Tests: ETH-PT
Order of Investigation
Ethernet Local Loop-Around Test (#1278)
TCP/IP Ping Test (#1281)
Session Status Test (#1286)
Link Integrity Inquiry Test (#1282)
1.
D = Destructive, ND = Non-destructive
555-233-119
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
Issue 5 October 2002
1
D/ND
D
ND
ND
ND