Table 243. TEST #1216 End Loopback/Span Test — Continued
Error
Test
Code
Result
2000
ABORT
Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more
of the following symptoms may be exhibited.
1313
FAIL
The TN767E DS1 circuit pack could not deactivate the loopback through the
Customer Loopback Jack.
1314
FAIL
The TN767E DS1 circuit pack could not deactivate the loopback through the
far-end CSU.
PASS
The active long-duration loopback or span test on the TN767E circuit pack
was successfully terminated.
1142
Issue 5 October 2002
Description/ Recommendation
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error
code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of the trunks for this circuit pack are placed into the out of
service state. The system will try to restore the circuit pack within 15
minutes. When no faults are detected for 15 minutes, the DS1
interface circuit pack is restored to normal operation. All of the trunks
for the DS1 interface circuit pack are then returned to the in service
state. Hyperactivity is often caused by the associated facility. In such a
case, faults (such as slips, misframes, or blue alarms) would be
entered in the error log. In addition, many hardware errors would be
logged against the associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, escalate this problem.
1. Retry the test ds1-loop UUCSS end-loopback/span-test command at
1-minute intervals for a maximum of 5 times.
1. Make sure that the far-end DS1 is installed if the far-end CSU is a 120A
CSU Module/T1 Sync Splitter.
2. Retry the test ds1-loop UUCSS end-loopback/span-test command at
1-minute intervals for a maximum of 5 times.
Continued on next page
555-233-119