PR-MAINT (Maintenance Processor)
MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a
query from a maintenance process to the MTP. The MTP must reply for the test to
pass.
Table 414. TEST #106 MTP Sanity Handshake Test
Error
Test
Code
Result
1029
ABORT
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
1000
ABORT
2033
ABORT
FAIL
PASS
555-233-119
Description/ Recommendation
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
System software resources required to run this test are not available.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the "long" option.
2. If the test continues to fail, replace the Processor circuit pack.
The MTP responded to the Sanity Handshake Query.