RANL-STA (Remote Analog Line (Station) Port)
Table 434. TEST #35 Battery Feed Test — Continued
Error
Test
Code
Result
1392
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
555-233-119
Description/Recommendation
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port
command (the display shows that the port is a TTI port) or the list
config command (the display shows a t for the port).
2. If the port is not a TTI port, escalate the problem. If both
commands indicate that the port is a TTI port, the abort is correct
for the test, and no action is necessary.
Response to the test request was not received within the allowable
time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The port's battery feed chip is unable to supply sufficient power to the
terminal equipment. This could be a marginal test, and the terminal
equipment may be operating satisfactorily.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, determine whether the customer is
experiencing problems on this line. Replace the circuit pack only
if the customer is experiencing problems.
The port's battery feed chip is able to provide power to the station
equipment to detect on-/off-hook, but may not be able to supply
power for touch-tones. If touch-tones are inoperative on this station,
then replace the circuit pack because this port is inoperative.
User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the
station.
Continued on next page
Issue 5 October 2002
1549