Maintenance Objects
Figure 23. Path of the BRI Port Local TDM Loop Around
Table 112. TEST #619 BRI Port Local TDM Loop Around
Error
Test
Code
Result
1000
ABORT
1002
ABORT
808
Issue 5 October 2002
Tone
Generator
BRI Line
Description/ Recommendation
The system resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command to
determine the station extension or trunk group/member number of the port.
Use the status bri-port PCSSpp command to determine the service state
of the port. If the service state indicates that the port is in use, the port is
unavailable for certain tests. Wait until the port is idle before retesting.
1. If the port is idle, retry the command at 1-minute intervals a maximum
of 5 times.
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
Tone
Detector
TDM Bus
Board