DIG-IP-STN (Digital IP Station)
Table 193. DIG-IP-STN Digital IP Station Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
1537(h)
40968
2305(i)
Any
None
2817(j)
Station Hyperactivity
Notes:
a. Error Type 1: this error reports the registration status of the endpoint. If call
processing SW claims the endpoint is registered and receives keep-alive
handshakes from the endpoint, the test passes. If keep-alive handshaking
has failed, the test fails. If the user has intentionally un-registered from the
Avaya MultiVantage Software, the station is now basically an AWOH
station and is no longer being maintained; no tests run for this station.
b. Error Type 18: this error type is logged when the port/station is busied out
by maintenance personal. Make sure the port/station is released from busy
via the release port/station command (IP terminal only).
c. Error Type 257: this error tracks failures of the signaling path PING test.
The test attempts to send a PING packet to the endpoint IP address, as
reported during registration. The PING packet originates with the C-LAN
board through which the endpoint is registered. If the PING response
packet is received, the test passes. If the PING response packet times out,
the test fails.
d. This is a refresh of the lamp states for all lamps on the Virtual DCP station.
The update always passes, if it runs successfully. It can abort, but it never
fails. This update is the same update used for existing DCP stations. It is
test number 16.
e. This is a refresh of the ringer state on the Virtual DCP station and a query
of the virtual station's switch-hook state. The audit always passes, if it runs
successfully. It can abort, but it never fails. This runs a subset of the
complete audit update that runs for standard DCP sets.
f. Error Type 513: this error type indicates that the terminal failed to respond
to the ID Query request. This implies that there is something wrong with the
terminal or the communication path. (IP terminal only).
g. Error Type 1281: this error type indicates that the terminal is reporting a
bad state of health (IP terminal only).
h. Error Type 1537: this error type indicates that the link has gone down
between the terminal and its gateway to the switch. This likely means that
the terminal has unregistered (IP terminal only).
555-233-119
Alarm
On/Off
Level
Board
WARNING
OFF
Continued on next page
Issue 5 October 2002
Test to Clear Value
test port or station
1015