Maintenance Objects
Table 353. TEST #53 SAKI Sanity Test — Continued
Error
Test
Code
Result
Description/ Recommendation
PASS
The circuit pack initializes correctly.
Run the short test sequence.
Any
NO
This is normal if the test is being done when (a) the board is not
BOARD
physically in the system or (b) the system is booting up. Otherwise,
there is some inconsistency between the physical configuration and
the data kept in the system.
Verify that the board is physically in the system.
Verify that the system is not in a stage of booting up.
Retry the command at 1-minute intervals for a maximum of 5 times.