Maintenance Objects
Table 504. Seizure Tests (#73, #747, #73)
Error
Test
Code
Result
ABORT
1000
ABORT
1004
ABORT
1005
ABORT
1018
ABORT
1708
Issue 5 October 2002
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The trunk may
be busy with a valid call. Use the display trunk xx to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), then
check the Error Log for Error Type 1025 (see Error Log table for
description of this error and required actions). The port may be locked
up. The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
(Non-TN497 circuit packs only.) The port was seized by a valid call during
the test. The test has been aborted. Use the display trunk xx to determine
the trunk group/member number of the port. Use the status trunk
command to determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for certain tests. You
must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test is not valid for this trunk translation. For this test to run, a delay
dial trunk (or, for non-TN497 circuit packs, a wink-start trunk) must be in
effect, and the trunk must be outgoing or two-way. Also, for the TN2140B,
the trunk must be continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this
abort message should be ignored. (For the TN2140B, disregard this
abort on a trunk that is not continuous-seize-ack or
discontinuous-seize-ack.)
Test disabled via administration.
1. Verify that the
Maintenance Tests?
Form is set to n. To enable the test, issue the change trunk-group x
command where "x" equals the number of the trunk group to be tested.
Then change the entry in the
form to y.
field on the Trunk Group
Maintenance Tests?
Continued on next page
field on the