DIG-LINE (Digital Line)
Only one value (Pass. Fail, or Abort) is generated as a result of the two tests run.
If any test fails aborts, the sequence is stopped. Upon completion of this test the
associated endpoint and port are moved back into the previous service state.
Table 203. TEST #1201 Digital Terminal Remote Loop Around Test
Error
Test
Code
Result
ABORT
1000
ABORT
1001
ABORT
1002
ABORT
1003
ABORT
555-233-119
Description/ Recommendation
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension or attendant number of the port. Use
status station or status attendant to determine the service state of the
port. If the service state indicates that the port is in use, then the port is
unavailable for certain test. You must wait until the port is idle before
re-testing. Attendants are always in use (off-hook) if the handset is plugged
in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
System resources required to run this test are not available.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM-Bus) Maintenance to diagnose
any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out of service.
1. Look for TTR-LEV errors in the Error Log. If present refer to TTR-LEV
(TTR-Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
(Tone Generator) Maintenance documentation.
3. If neither condition exist, retry the command at 1-minute intervals a
maximum of 5 times.