Table 175. TEST #109 Data Channel Remote Maintenance Loop Around Test — Continued
Error
Test
Code
Result
30
ABORT
31
32
33
40
41
70
75
1000
ABORT
960
Issue 5 October 2002
Description/Recommendation
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
For this test, an Error Code of 1000 can have one of several different
meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. No other DATA-CHLs are administered and, therefore, not available to
place the call to the target DATA-CHL.
c. All other DATA-CHLs are busy and, therefore, not available to place
the call to the target DATA-CHL.
d. System resources required to run this test are not available.
e. Internal system error
Note the results of Tests #110 and #111 in the Short Test Sequence for the
target DATA-CHL. If the results of Tests #110 and #111 are both PASS, then
there is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
1. Determine if the target DATA-CHL is in use for some other function (that
is, CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the "Status of network Control Data Channels" section. If so, check for
errors on the function that is using the DATA-CHL. If there are no errors,
there is a high probability that the DATA-CHL is not defective. Proceed
with the remaining steps only if it is necessary to completely test the
target DATA-CHL.
2. If the target DATA-CHL is in use for some other function, busyout the
function (CDR Link, System Printer Link, Journal Printer Link, PMS Link)
or the DATA-CHL (secondary administration terminal connection only).
Continued on next page