Maintenance Objects
Error Log Entries and Test to Clear Values
Table 399. PMS-PRNT/JNL-PRNT Link Maintenance Error Log Entries
Error
Aux
Type
Data
1
0
0
18 (a)
0
257 (b)
0,
3 to 6
255
513 (c)
0,
3 to 6
255
769 (d)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Both PMS Printer and Journal Printer are administered to the same extension, and the printer is
not connected. Refer to the
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
Notes:
a. System Technician busied out the Journal Printer Link. The link is torn
down. Enter release command to restore the link.
b. Link Retry Test (#215) fails. Physical link cannot be set up, usually because
of hardware problems such as power off or cable disconnect. The Aux Data
field contains the Channel ID of Data Channels on Network Control circuit
pack (that is, 3 for Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for
Channel 04), an Error Code 255 for the Internal system error, or 0 which
indicates that the data module connected to the PMS Printer Link is
out-of-service. Refer to
section for resolution.
1492
Issue 5 October 2002
Associated Test
Alarm Level
Any
Any
busyout journal
WARNING
wakeup-log/
pms-log
Link Retry Test
MINOR/
(#215)
WARNING
''Procedures for Restoring the PMS Printer Link''
''Procedures for Restoring the PMS Printer Link''
On/Off
Board
Test to Clear Value
Any
test journal
wakeup-log|pms-log sh
OFF
release journal
wakeup-log|pms-log
OFF
test journal
2
wakeup-log|pms-log 1
test journal
wakeup-log|pms-log
section for resolution.