Avaya DEFINITY Server CSI Maintenance Manual page 1679

Table of Contents

Advertisement

TIE-DS1 (DS1 Tie Trunk)
Notes:
a. Error Type 1—The DS1 Interface circuit pack detects a hardware error on
the DS1 tie trunk. This error can be caused by incompatible translations.
Make sure the parameters administered on the DS1 circuit pack form
match those administered on the far-end switch.
The Aux Data field indicates the following hardware error types:
57476
57477
57485
57487
If all administration errors between the switch and the far-end match, and
these errors continue to recur, follow normal escalation procedures.
b. Error Type 15—This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate
associated errors (if any).
c. Error Type 18—The DS1 tie trunk has been busied out by a busyout trunk
grp/mbr command. No calls can be made on this trunk except for the
Facility Access Test Call.
d. Error Type 19—This error type indicates that the far-end may be
out-of-service, or the Electronic Tandem Network may be busied out.
e. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
f. Error Type 257—The DS1 Interface circuit pack detects a hardware error
on the DS1 tie trunk. The trunk cannot communicate with the far end
because it is unable to interpret digits sent from the far-end switch. The
Aux Data field indicates the following:
57473
57474
Check with the far-end switch or operating company for proper trunk
connection.
g. Error Type 513—DS1 Interface circuit pack detects a hardware error on the
DS1 tie trunk. The trunk is in-service/active and waiting for an "on-hook"
from the far-end switch. No calls can be routed over the trunk while it is in
this state. Aux Data 57392 indicates no external release on PBX
disconnect. Check with the far-end switch or operating company for proper
trunk connection.
555-233-119
On-hook before wink
On-hook before ready to receive digits
Wink too short for valid signal
The timer expired while waiting for an off-hook
signal from the far end as a response at end of digits
dialing. Check the far-end switch for related
problems.
The rotary dial rate is below 8 pulses per second.
The rotary dial rate is above 12 pulses per second.
Issue 5 October 2002
1679