Maintenance Objects
Nonvolatile Memory
Nonvolatile memory stores downloadable parameters in programmable terminals.
Once the terminal is downloaded, it is not be necessary to download it again, even
if power is removed from the terminal. If nonvolatile memory fails with power still
present, the terminal reverts to its default factory settings except for its
A-law/mu-law companding settings which are stored in RAM. If power is removed
after the nonvolatile memory fails, the terminal reverts to its factory default
settings.
NOTE:
The mu-law companding mode is assigned as a default setting at the
factory. For the United States, a programmable terminal can place calls
even though it has not been downloaded from the system.
Download Actions
There are several different scenarios which causes a terminal to be downloaded.
These can occur as part of background maintenance activity or on demand from
the System Access Terminal (SAT) or from a station.
For the background actions described below, the terminal downloads
automatically if a download retry flag for the terminal is set in software. This flag is
set at the time translation is loaded at boot time, when the translation that affects
the parameters of a terminal is changed as part of system administration actions,
or when a port is inserted in software as a result of board insertion or translation
change.
Automatic Download Actions
1. System Reboot/Restart
A global download action is initiated when periodic maintenance tests
begin after a system reboot/restart, regardless of whether the parameters
have been downloaded previously.
2. Periodic Tests
If the download flag is still set when periodic tests are run on a terminal, a
download action will occur. This action is required in case a terminal could
not be downloaded previously, because:
1556
Issue 5 October 2002
It was off-hook at the time the system first booted, or
The terminal was off-hook at the time the translation associated with
downloadable parameters was changed.
NOTE:
It may take more than an hour for periodic tests to reach the terminal
that needs to be downloaded.