BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Table 114. TEST #621 Level 1 Status Inquiry — Continued
Error
Test
Code
Result
1
FAIL
555-233-119
Description/ Recommendation
Received a status of Level 1 Pending Activation-Endpoint Idle which
indicates a problem with the BRI endpoint or ASAI or adjunct, the wiring to
the endpoint or adjunct, or the ISDN-BRI port.
For the TN2198, received a status of Level 1 Pending Activation. U
interface down, which indicates a problem with a connection between the
switch and the NT1.
NOTE:
An NT1 is a 2- to 4-wire converter that is used to connect 4-wire
terminals to a 2-wire TN2198 circuit pack. The NT1 also has status
lamps to determine the health of the unit.
1. For the TN556 or TN2208, verify that an endpoint is connected to the
port. If an endpoint is connected to the port, go to Step 2. For the
TN2198 verify that the connections are good between the switch and
the NT1. Verify that the NT1 has power.
2. As necessary, check and repair the wiring between the circuit pack and
the endpoint or adjunct. If a TN2198 is used, the set must have been
plugged in for at least 15 seconds before it will stabilize. Execute the
test port PCSSpp command, and review the results of the Level 1
Status Inquiry Test to verify the repair. If this test is still fails, go to Step
3.
3. For BRI endpoints, replace the BRI endpoint(s) connected to the port or
the NT1 if a TN2198 is used. For ASAI or adjuncts, follow the
recommended repair procedures of the manufacturer for link
communication problems. For the NT1, follow the manufacturers repair
procedures. Then execute test port PCSSpp and review the results of
the Level 1 Status Inquiry Test to verify repair. If this test still fails, go to
Step 4.