Avaya DEFINITY Server CSI Maintenance Manual page 954

Table of Contents

Advertisement

Error Log Entries and Test to Clear Values
Table 171. Data Channel Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
(a)
0
Any
1
Any
Local Loop Back Test
(#111)
18
0
busyout data-module
<ext>
130
None
257
Any
Remote Maintenance
Loop Around Test
(#109)
513
Any
Crosstalk Test (#110)
769
Any
Dual Port RAM Test
(#108)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
954
Issue 5 October 2002
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
WARNING
ON
MINOR
ON
MINOR
ON
MINOR
ON
Test to Clear Value
test data-module <ext> sh r 1
test data-module <ext> sh r 3
release data-module <ext>
test data-module <ext> sh
test data-module <ext> sh r 5
test data-module <ext> sh r 3
test data-module <ext> l r 3
555-233-119