ATM-TRK (Circuit Emulation Service Circuit Pack)
Table 100. ATM Board Error Query Test (#1259)
Error
Test
Code
Result
Description/Recommendation
2000
ABORT
Test request timed out.
2031
ABORT
SCD failure. Unable to sent down-link message.
2100
ABORT
Could not allocate needed system resources.
2500
ABORT
Internal system error
Retry the command up to 3 times at 1-minute intervals.
XXYY
FAIL
On-board error XX
778).
Examine the error logs and repair any errors found.
PASS
The ATM circuit pack has passed this test. No service effecting errors/alarms
have been detected on board.
0
NO
ATM-TRK circuit pack not found
BOARD
Check the error log, and correct Error 125 (wrong board) or Error 131 (no
board), if found.
Make sure that the board is properly translated and inserted.
Check for hyperactivity (Error 1538). Run reset board UUCSS if
hyperactive.
Run the test again. If it fails, replace the board, and retest.
Aux Data XX
Table 101. Aux Data XX for ATM Board Error Query Test (#1259)
If XX=
Then
1
ATM framer chip failed
2
NCE chip failed
3
LANHO critical error
4
TDM Programmable Logic Device Failed
5
All on-board DSPs failed
6
Receive Network Processor failed
555-233-119
(Table
101) and/or off-board error YY
(Table 102 on page
Continued on next page
Continued on next page
Issue 5 October 2002
777