Cabinet (Cabinet Sensors) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Objects

CABINET (Cabinet Sensors)

MO Name (in
Alarm Log)
CABINET
1.
Where P is an appropriate port network number determined in the Port field from the
Alarm or Error Log.
The Compact Modular Cabinet (CMC) AC Power Supply (650A) supports one
alarm lead that indicates the state of both the power and fan. With multiple
cabinets, alarm leads from each cabinet are tied into a single lead. The CMC uses
variable speed fans to reduce noise. The CMC power unit contains Thermal
Speed Control and an alarm circuit. A variable speed fan has a 3-pin connector for
the variable input power for speed control and its alarm circuitry.
See the next table for the LED and alarm conditions.
Condition
Normal
No input power
DC output not present
(except Neon)
Fan alarm
846
Issue 5 October 2002
Initial Command to
Alarm Level
MAJOR
test environment P
LED Status
Alarm State
Red off;
Open
Yellow on
Red off;
Closed
Yellow off
Red on;
Closed
Yellow off
Red on;
Closed
Yellow on
1
Run
Full Name of MO
Cabinet Sensors
Fan Alarm
Normal
No input power
DC output not present (except Neon)
Fan alarm
555-233-119