Advertisement

TONE-PT (Tone Generator)
Table 513. TEST #40 Tone Generator Transmission Test
Error
Test
Code
Result
None
ABORT
1
ABORT
1001
ABORT
1002
ABORT
1003
ABORT
1022
ABORT
2000
ABORT
2100
ABORT
1 (a)
FAIL
105 (a)
FAIL
109 (a)
FAIL
110 (b)
FAIL
555-233-119
Description/ Recommendation
The system was not able to allocate all the resources needed for this test or
there was an Internal System Error.
The system could not allocate all the resources needed to test the DTMF
tones.
The system was not able to put the tone generation facility in the
appropriate mode to test it.
The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm port-network PN#
command. Refer to TDM-BUS section for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test connection. This
can happen when the system is heavily loaded or there is not a Tone
Detector circuit pack in the port network where this test is being executed.
1. Make sure there is a Tone Detector circuit pack installed.
2. Allow approximately 1 minute for Tone Detector maintenance to run on
the newly inserted Tone Detector circuit pack.
3. Retry the command at 1-minute intervals a maximum of 5 times.
Tone detection for the system is administered as wide broadband (tone
detection mode 5), and the Tone Detector used for this test was not a
TN2182. GPTD ports on other types of Tone Detector circuit packs are
taken out of service since they cannot provide the administered function.
1. Change the tone-detection mode administered on the
system-parameters country-options form.
Or
2. Remove all non-TN2182 circuit packs from the system.
Response to the test request was not received within the allowable time
period. System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
DTMF generation failed for the active tone generator.
Generation of 440-Hz failed.
Generation of 2225-Hz failed.
Generation of 404-Hz level invalid.
Continued on next page
Issue 5 October 2002
1733